If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DE DIETRICH DHD519XE1. We hope that this DE DIETRICH DHD519XE1 user guide will be useful to you.
You may also download the following manuals related to this product:
DE DIETRICH DHD519XE1 (2452 ko)
DE DIETRICH DHD519XE1 (175 ko)
DE DIETRICH DHD519XE1 (187 ko)
DE DIETRICH DHD519XE1 (335 ko)
DE DIETRICH DHD519XE1 (357 ko)
DE DIETRICH DHD519XE1 (439 ko)
DE DIETRICH DHD519XE1 (359 ko)
DE DIETRICH DHD519XE1 (361 ko)
Manual abstract: user guide DE DIETRICH DHD519XE1
Detailed instructions for use are in the User's Guide.
[. . . ] The specific instructions are described in the booklet section intended for the installer.
USING THE BURNERS
The symbols silk-screen printed on the side of the knob indicate the correspondence between the knob and the burner. Automatic start-up with valves Turn the corresponding knob anticlockwise up to the maximum position (large flame, fig. Once the burner has been started up, keep the knob pressed for about 6 seconds. Using the burners In order to obtain the maximum yield without Fig. 1 waste of gas, it is important that the diameter of the pot is suitable for the burner potential (see the following table), so as to avoid that the flame goes out of the pot bottom (fig. [. . . ] - When the burner is started up, check that the flameis regular and, before taking pots away, always lowerthe flame or put it out.
Fig. 2 Use the maximum capacity to quickly make the liquids reach the boiling temperature, and the reduced capacity to heat food or maintain boiling. All of the operating positions must be chosen between the maximum and the minimum ones, never between the minimum position and the closing point. Use the maximum capacity to quickly make the liquids reach the boiling temperature, and the reduced capacity to heat food or maintain boiling. All of the operating positions must be chosen between the maximum and the minimum ones, never between the minimum position and the closing point. The gas supply can be interrupted by turning the 4
ELECTRIC PLATE USE
The electric-plate is operated with a seven position switch and to turn the electric-plate on, rotate the switch to any of the positions shown. Below as indicative basis, the settings to be used for operating the electric-plate. Warning - Use only flat pans and with sufficiently thick base, equal or not much superior than that of the plate. - Turn off the plate few minutes before the cooking end.
INSTRUCTIONS FOR THE USER
- After use the electric plate remains very hot for a prolonged period of time, do not tuch it and do not place any object on top of the plate. - For a good preservation, the electric plate must be thoroughly cleaned with appropriate cleaning products which are readly available. KNOB SETTING 0 1 2 3 4 5 6 NB. : When operating for the first time, it is necessary to eliminate any humidity or oil which may accumulated around the electric elements of the plate by operating the electric plate on its lowest setting (1) for about 30 minutes.
HEAT Off Very low Low Mild Medium Strong Very strong
TYPE OF COOKING
To heat small quantities of liquids. Heating medium quantities of liquid, to prepare sauces and creams requiring long cooking. 6
- Introduce and place the cook-top in the hole made in the piece of furniture, then block it with the V screws of the fastening hooks G (fig. 6. Installation room This appliance is not provided with a device for exhausting the products of combustion. Regarding
INSTRUCTIONS FOR THE INSTALLER
room ventilation rules where appliance is installed make reference to the legislation, in conformity with the local regulations. ONLY The room containing this hotplate should have an air supply in accordance with BS 5440: Part 2: 1989. - All rooms require an openable window, or equivalent and some rooms will require a permanent vent a well. - For room volumes between 5 m3 and 10 m3 an air vent of 50 cm2 is required. - If the room is greater than 5 m3 and has a door that opens directly to the outside, then no air vent is required. If there are other fuel burning appliances in the same room BS 5440: Part 2:1989 should be consulted to determine the air vent requirements. Gas connection Make sure that the appliance is adjusted for the gas type available (see the label under the appliance). Follow the instructions indicated in the chapter "gas transformations and adjustments" for the possible adaptation to different gases. The appliance must be Fig. 7 connected to the gas system by means of stiff metal pipes or flexible steel pipes having continuous walls, in compliance with the regulations in force. [. . . ] Make sure that the electric system is 7 provided with an effective ground connction in compliance with the regulations and provisions of the law. If the appliance is not equipped with a plug, apply a standardized plug to the power supply cable. 60 Reg.
NOMINAL HEAT INPUT (W) Max.
3000 3000 1750 1750 1000 1000 3800 3800
DESCRIPTION
L/h
290 165 99 367
Min.
950 950 600 600 450 450 2100 2100
RAPID SEMI-RAPID AUXILIARY TRIPLE CROWN
G30 / G31 G20 G30 / G31 G20 G30 / G31 G20 G30 / G31 G20
28 - 30 / 37 20 28 - 30 / 37 20 28 - 30 / 37 20 28 - 30 / 37 20
2
3
4
This product complies with EU Directive 2002/96/EC.
The crossed-out dustbin symbol reported on the appliance indicates that the appliance must be disposed of separately from other domestic refuse at the end of its useful life. It must therefore be delivered to a waste recycling centre specifically for electric and electronic equipment or returned to the retailer at the moment of purchase of a new equivalent appliance. [. . . ]