User manual DE DIETRICH 6435EN

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DE DIETRICH 6435EN. We hope that this DE DIETRICH 6435EN user guide will be useful to you.


DE DIETRICH 6435EN : Download the complete user guide (2282 Ko)

You may also download the following manuals related to this product:

   DE DIETRICH 6435EN (1121 ko)
   DE DIETRICH 6435EN (1095 ko)
   DE DIETRICH 6435EN (1030 ko)
   DE DIETRICH 6435EN (1240 ko)
   DE DIETRICH 6435EN (2128 ko)
   DE DIETRICH 6435EN (5785 ko)
   DE DIETRICH 6435EN (2141 ko)
   DE DIETRICH 6435EN (2140 ko)

Manual abstract: user guide DE DIETRICH 6435EN

Detailed instructions for use are in the User's Guide.

[. . . ] - Before carrying out the maintenance or cleaning the equipment, cut power supply off and make it cool down. - In case of an intense or prolonged use of the equipment, it may be necessary to improve aeration, for example by opening a window or increasing the mechanical suction power, if it exists. - The products of combustion must be discharged outside through a suction hood or an electric fan (see the "installation" paragraph). - For any possible operation or modification, apply to an authorized Technical Assistance Centre and demand original spare parts. The product label, with the serial number, is sticked under the hob. The manufacturer refuses all responsibility for possible damages to things or people, resulting from a wrong installation or from an improper, incorrect or unreasonable use of this equipment. [. . . ] To restore operation, set the knob to the lighting point (large flame, fig. - While cooking with fat or oil, pay the utmost attention as these substances can catch fire when overheated. - Do not place unstable or deformed pots on the burner, so as to prevent them from overturning or overflowing. - When the burner is started up, check that the flameis regular and, before taking pots away, always lowerthe flame or put it out. Fig. 2 Use the maximum capacity to quickly make the liquids reach the boiling temperature, and the reduced capacity to heat food or maintain boiling. All of the operating positions must be chosen between the maximum and the minimum ones, never between the minimum position and the closing point. Use the maximum capacity to quickly make the liquids reach the boiling temperature, and the reduced capacity to heat food or maintain boiling. All of the operating positions must be chosen between the maximum and the minimum ones, never between the minimum position and the closing point. The gas supply can be interrupted by turning the 4 ELECTRIC PLATE USE The electric-plate is operated with a seven position switch and to turn the electric-plate on, rotate the switch to any of the positions shown. Below as indicative basis, the settings to be used for operating the electric-plate. Warning - Use only flat pans and with sufficiently thick base, equal or not much superior than that of the plate. - Turn off the plate few minutes before the cooking end. INSTRUCTIONS FOR THE USER - After use the electric plate remains very hot for a prolonged period of time, do not tuch it and do not place any object on top of the plate. 5). Fig. 3 MODEL DTE714X / W / F / B DTE715X / W / F / B DTE772X / W / F / B DTG764X DTG775X DTE792X DTG795X L (mm) P (mm) 560 480 860 480 Fig. 5 Fig. 6 Any possible wall unit over the cook-top must be placed at a distance of at least 760 mm from the top. It is advisable to isolate the appliance from the piece of furniture below with a separator, leaving a depression space of at least 10 mm (fig. 6 - Introduce and place the cook-top in the hole made in the piece of furniture, then block it with the V screws of the fastening hooks G (fig. 6. Installation room This appliance is not provided with a device for exhausting the products of combustion. Regarding INSTRUCTIONS FOR THE INSTALLER room ventilation rules where appliance is installed make reference to the legislation, in conformity with the local regulations. ONLY The room containing this hotplate should have an air supply in accordance with BS 5440: Part 2: 1989. - All rooms require an openable window, or equivalent and some rooms will require a permanent vent a well. - For room volumes between 5 m3 and 10 m3 an air vent of 50 cm2 is required. - If the room is greater than 5 m3 and has a door that opens directly to the outside, then no air vent is required. If there are other fuel burning appliances in the same room BS 5440: Part 2:1989 should be consulted to determine the air vent requirements. Gas connection Make sure that the appliance is adjusted for the gas type available (see the label under the appliance). [. . . ] If the appliance is not equipped with a plug, apply a standardized plug to the power supply cable. It is possible to effect the connection to the electric grid directly, by interposing an omnipolar switch having a contact opening distance of at least 3 mm. GAS TRANSFORMATIONS AND ADJUSTMENTS Replacing the nozzles If the equipment is adjusted for a type of gas that is different from the one available, it is necessary to replace the burner nozzles. It must therefore be delivered to a waste recycling centre specifically for electric and electronic equipment or returned to the retailer at the moment of purchase of a new equivalent appliance. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DE DIETRICH 6435EN




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DE DIETRICH 6435EN will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.