User manual CASIO WK-500

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CASIO WK-500. We hope that this CASIO WK-500 user guide will be useful to you.


CASIO WK-500 : Download the complete user guide (342 Ko)

You may also download the following manuals related to this product:

   CASIO WK-500 (6898 ko)
   CASIO WK-500 (5140 ko)
   CASIO WK-500 (7058 ko)
   CASIO WK-500 (1710 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)
   CASIO WK-500 APPENDICE (1298 ko)

Manual abstract: user guide CASIO WK-500

Detailed instructions for use are in the User's Guide.

[. . . ] CTK-4000/CTK-5000/LK-270/LK-205/WK-200/WK-500/CDP-200R MIDI Implementation CASIO COMPUTER CO. , LTD. Contents Part I 1 1. 1 1. 2 1. 3 MIDI Message Overview System Section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Performance Controller Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Sound Generator Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1. 3. 1 Sound Generator Common Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] For more information, see "11. 1 About the Timbre Type" below. 11. 1 About the Timbre Type Tones that are selected by each Instrument part have an attribute that depends on the sound source operation type. This attribute is called the "timbre type, " which is one of the types described below. · · Melody This timbre type optimizes for normal melody tones. The Hold1, Channel Coarse Tune, and Master Coarse Tune messages are ignored if they are received. 17 12 Format Channel Aftertouch Message Format: DnH vvH n: MIDI Channel Number vv: Value Send These messages are never sent. Receive Receipt of this message adds modulation to the voice that is sounding. The modulation effect differs according to the tone being used. 13 Format Pitch Bend Message Format: EnH llH mmH n: MIDI Channel Number ll: Value LSB mm: Value MSB Send Sent when a pitch bender operation is performed on the CTK-5000, WK-500, or CDP-200R. The range of the pitch change depends on the Bend Range value setting. 18 Part III System Messages 14 Format Message Format: F8H Send Sent when auto accompaniment is used. Receive This message is not received by this Instrument. Timing Clock 15 Format Start Message Format: FAH Send Sent when auto accompaniment is used. Receive This message is not received by this Instrument. 16 Format Stop Message Format: FCH Send Sent when auto accompaniment is used. Receive This message is not received by this Instrument. 17 Format Active Sensing Message Format: FEH Send This message is never sent. 19 Receive Once this message is received, the Active Sensing mode is entered. If no MIDI message is received for a specified amount of time, voices being sounded by the Instrument's sound source are released, the controller is reset, and the Active Sensing mode is exited. 18 Format System Exclusive Message Message Format: F0H. . . . F7H The Instrument sends and receives standard universal system exclusive messages, and system exclusive messages that have Instrument-specific formats. 18. 1 Format Universal Realtime System Exclusive Message Message Format: F0H 7FH. . . . F7H 18. 1. 1 Format Master Volume Message Format: F0H 7FH 7FH 04H 01H llH mmH F7H ll: LSB Value mm: MSB Value Send This message is never sent. Note that the Master Volume parameter cannot be changed with an Instrument operation. 18. 1. 2 Format Master Fine Tuning Message Format: F0H 7FH 7FH 04H 03H llH mmH F7H mm: MSB Value(Note1) Note 1: For information about the relationship between setting values and send/receive values, see "33. 4 -100 - 0 - +99 Setting Value Table" in "Part VII Setting Values and Send/Receive Values" of this document. Receive Receipt changes the tuning setting. 20 18. 1. 3 Format Master Coarse Tuning Message Format: F0H 7FH 7FH 04H 04H 00H mmH F7H ll: LSB Value mm: MSB Value Send Sent when Transpose is changed. Does not affect sound source operation when the Timbre Type is Drum. 18. 1. 4 Format Reverb Parameter Message Format: F0H 7FH 7FH 04H 05H 01H 01H 01H 01H 01H ppH vvH F7H pp: Parameter vv: Value Time Format Message Format: F0H 7FH 7FH 04H 05H 01H 01H 01H 01H 01H 01H vvH F7H vv: Value (Note1) Note 1: For information about the relationship between setting values and send/receive values, see "33. 5 Reverb Time Setting Value Table" in "Part VII Setting Values and Send/Receive Values" of this document. Receive Receipt changes the Reverb duration. 18. 1. 5 Format Chorus Parameter Message Format: F0H 7FH 7FH 04H 05H 01H 01H 01H 01H 02H ppH vvH F7H pp: Parameter vv: Value Type Format Message Format: F0H 7FH 7FH 04H 05H 01H 01H 01H 01H 02H 00H vvH F7H vv: Value (Note1) 21 Note 1: For information about the relationship between setting values and send/receive values, see "33. 6 Chorus Type Setting Value Table" in "Part VII Setting Values and Send/Receive Values". Send This message is sent when the System Chorus Type setting is changed. Receive Receipt changes the System Chorus Type parameter. Rate Format Message Format: F0H 7FH 7FH 04H 05H 01H 01H 01H 01H 02H 01H vvH F7H vv: Value (Note1) Note 1: The setting value matches the value that is sent and received. Receive Receipt changes the System Chorus Rate parameter. 18. 1. 6 GM System Message GM System On Format Message Format: F0H 7EH 7FH 09H 01H F7H Send This message is never sent. Receive Receipt puts the sound source into a GM sound source mode. GM System Off Format Message Format: F0H 7EH 7FH 09H 02H F7H Send This message is never sent. Receive Receipt changes the sound source setting to the Instrument presetting. GM2 System On Format Message Format: F0H 7EH 7FH 09H 03H F7H Send This message is never sent. Receive Though the Instrument does not support GM2, receipt of the GM2 System On message has the same result as receipt of the GM System On message. 22 18. 1. 7 GS Message Note: dd (Device ID) is ignored. Message Format: F0H 41H ddH 42H 12H 40H 00H 7FH 00H 41H F7H Send This message is never sent. Receive Receipt performs the same operation as when the GM System On message is received. 18. 2 Format Instrument-Specific System Exclusive Message Message Format: F0H 44H 16H 01H. . . . F7H This message can be used to send the Instrument memory status, for two-way transfer of special operation commands and user data, to perform sound source parameter operations, etc. [. . . ] Specifies the memory ID of the parameter set that corresponds to an operation. Specifies the number of the parameter set that corresponds to an operation. Whether a parameter set exists in the specified category (0: No, 1: Yes). Protect status of a parameter set data in the specified category (0: Off, 1: On). These are information acquisition and operation command parameters for this Instrument's Data Manager PC application. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CASIO WK-500




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CASIO WK-500 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.