User manual CANDY CHW6LBB
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CANDY CHW6LBB. We hope that this CANDY CHW6LBB user guide will be useful to you.
You may also download the following manuals related to this product:
CANDY CHW6LBB (1128 ko)
CANDY CHW6LBB (1704 ko)
Manual abstract: user guide CANDY CHW6LBB
Detailed instructions for use are in the User's Guide.
[. . . ] It is strongly recommended to keep children away from the cooking zones while they are in operation or when they are switched off, so long as the residual heat indicator is on, in order to prevent the risks of serious burns. This appliance is not intended to be operated by means of an external timer or separate remote control system. Connect a plug to the supply cable that is able to bear the voltage, current and load indicated on the tag and having the earth contact. The socket must be suitable for the load indicated on the tag and must be having the earth contact connected and in operation. [. . . ] A gas-powered cooking appliance produces heat and humidity in the area in which it is installed. For this reason you should ensure good ventilation either by keeping all natural air passages open or by installing an extractor hood with an exhaust flue. Intensive and prolonged use of the appliance may require extra ventilation, such as the opening of a window or an increase in speed of the electric fan, if you have one. If a hood can not be installed, an electric fan should be fitted to an outside wall or window to ensure that there is adequate ventilation. The electric fan should be able to carry out a complete change of air in the kitchen 3-5 times every hour. Warning - this appliance must be earthed This appliance is designed for domestic use only. Connection to the main supply must be made by a competant electrician, ensuring that all current regulations concerning such installations are observed. The appliance must only be connected to a suitably rated spur point, a 3 pin 13 amp plug/socket is not suitable. A double pole switch must be provided and the circuit must have appropriate fuse protection. Further details of the power requirement of the individual product will be found in the users' instruction and on the appliance rating plate. In the case of built-in product you are advised, should you wish to use a longer cable than the one supplied, that a suitably rated heat resistant type must be used. The wiring must be connected to the mains supply as follows: Note: We do not advocate the use of earth leakage devices with Electric cooking appliances installed to spur points because of the You are again reminded that the Appliance must be correctly earthed, the manufacturer declines any If an appliance is not fitted with a supply cord and a plug, or with other means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvoltage category III conditions, the instructions shall state that means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. These instructions are for qualified personnel, installation of equipment must be in line with the relevant national standard. Only: by law the gas installation\commissioning must be carried out by a "Gas Safe" installer) All work must be carried out with the electricity supply disconnected. The rating plate on the hob shows the type of gas with which it is designed to be used. Connection to the mains gas supply or gas cylinder should be carried out after having checked that it is regulated for the type of gas with which it will be supplied. If it is not correctly regulated see the instructions in the following paragraphs to change gas setting. For liquid gas (cylinder gas) use pressure regulators which comply with the relevant national standards. Use only pipes, washers and sealing washers which comply with the relevant national standards. For some models a conic link is furnished to outfit for the installation in the countries where this type of link is obligatory; in picture 8 it is pointed out how to recognize the different types of links (CY = cylindrical, CO = conic). In every case the cylindrical part of the link has to be connected to the hob. When connecting the hob to the gas supply via use offlexible hoses please ensure that the maximum distance covered by the hose does not exceed 2 metres. [. . . ] Si la table est installée entre deux meubles de cuisine, la distance entre la table et les meubles doit être au moins de 15 cm (voir schéma 4); tandis que la distance entre la table et le mur du fond doit être au moins Lorsque vous achetez un nouvel appareil, vous devez retourner l'ancien au vendeur qui le récupère gratuitement, au cas par cas, à condition que l'équipement soit de type équivalent et possède les mêmes fonctions que celui fourni. Dac exist elemente cu lamp cu halogen, nu privii fix în acestea. Conecta i un techer la cablul de alimentare care s poat suporta tensiunea, curentul i sarcina indicate pe etichet i care s aib contact de împmântare. Conexiunea la o surs de alimentare poate fi realizat de asemenea prin aezarea unui disjunctor omnipolar între aparat i sursa de alimentare care s suporte sarcina maxim conectat i care s respecte legisla ia actual. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CANDY CHW6LBB
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CANDY CHW6LBB will begin.